Leave Your Message
Products Categories
Featured Products

China HART Data Collector Factory - 8-Channel HART to Ethernet & MODBUS-RTU/TCP Protocol Converter Suppliers

Introducing the SM100-M-8 HART Data Collector, a cutting-edge product developed by a leading factory in China, utilizing an ARM microprocessor and a state-of-the-art HART protocol modem chip. This data collector is engineered to meet the stringent demands of industrial applications, ensuring high reliability and stability under various conditions, Designed with an industry-standard RS485 interface and gateway, the SM100-M-8 enables seamless data transmission with smart instruments that utilize the HART protocol. Furthermore, it effectively converts data into MODBUS RTU or MODBUS TCP protocols, allowing for real-time data reading and transmission, As a trusted supplier in the market, we guarantee that the SM100-M-8 HART Data Collector will enhance your data management capabilities, making it an essential tool for your industrial operations. Experience the superior quality and performance that our factory in China offers

    Product Introduction

    A product called the SM100-M-8 HART data collector was created using an ARM microprocessor, a HART protocol modem chip, and a great deal of real-world experience. It offers great stability and dependability and is designed to meet the specifications of industrial items. To ensure real-time data transmission, the data collector is outfitted with a standard RS485 interface and gateway that can either convert data into MODBUS _ RTU or MODBUS _ TCP protocol to read data or transparently communicate data with intelligent instruments using HART protocol.

    The HART protocol instrument enables bidirectional data transmission without interfering with the 4 to 20 mA analog signal by superimposing a modulated digital signal on a 4 to 20 mA basis using the Bell202 Frequency Shift Keying (FSK) standard. An clever converter for bidirectional modulation and demodulation of digital and analog signals is the SM100-M series HART data collector.

    Product Features

    Support simultaneous connection of 8 HART devices.
    Support parallel and simultaneous scanning of all HART channels configured for the HART data collector.
    Three-terminal electromagnetic full quarantine between HART channels and between HART and host power supply. Each channel adopts two-wire interface. The voltage of electromagnetic quarantine of HART module is not less than 1500 V. It supports the function of separating HART signal/4 ~ 20ma signal.
    The quarantine voltage of RS485 interface and NET Ethernet interface shall not be lower than 1500 V.
    Adopt the modular design of separating the HART module from the host, and support the function of replacing the HART module online in any channel.
    Each channel is provided with an independent indicator light, which provides indication of HART equipment online and HART equipment communication status respectively.
    Equipped with equipment status indicator light: operation/fault, communication interface, etc.
    Data refresh rate per channel < 1 second.
    Support Ethernet interface (speed not less than 100Mbps) and RS485 interface.
    Support proprietary HART commands to read the HART ID of all HART devices.
    Support configuration and operation mode, and support Telnet remote setting.
    Support firmware program update.
    Supports standard DIN rail mounting.
    The equipment does not affect the transmission and accuracy of 4 ~ 20 mA analog signal in normal, power failure or fault, and the loop resistance is less than or equal to 250 ohms.
    This equipment does not supply power to field instruments.
    Compatible with HART protocol Ver5.0 and above.

    Main Parameters

    Power supply voltage
    DC 24V
    Operating current
    < 80mA
    Shell size
    305 mm long × 160 mm wide × 35 mm high
    Installation dimension
    347.4 mm (L) × 35 mm (W) × 160 mm (H)
    Working temperature
    -20 ℃ ~ + 75 ℃
    Humidity of working environment
    5% ~ 95% (no condensation)

    Frequently Asked Questions (FAQ)

    How many HART devices can the SM100-M-8 connect to?
    The SM100-M-8 HART data collector supports the simultaneous connection and parallel scanning of up to 8 HART devices.
    Does the collector affect the 4 to 20 mA analog signal?
    No, the equipment does not affect the transmission and accuracy of the 4 to 20 mA analog signal under normal operation, power failure, or fault conditions. The loop resistance is less than or equal to 250 ohms.
    What protocols are supported for data transmission?
    It supports RS485 and Ethernet interfaces, allowing data to be converted into MODBUS_RTU or MODBUS_TCP protocols, or transparently communicated using the HART protocol.
    Does the SM100-M-8 supply power to field instruments?
    No, this equipment does not supply power to field instruments.
    What is the operating voltage and current for this device?
    The required power supply voltage is DC 24V, and the operating current is less than 80mA.