8-Channel HART Data Collector - HART to Ethernet & MODBUS Converter from China Suppliers and Factory

The SM100-M-8 HART data collector, developed with advanced ARM microprocessor technology and a dedicated HART protocol modem chip, is a reliable solution tailored for industrial applications. As a leading product from China, our data collector ensures exceptional stability and high performance. This device features a standard RS485 interface and gateway, enabling seamless, transparent data transmission with HART protocol intelligent instruments. It can also convert data into MODBUS RTU or MODBUS TCP protocols for efficient data reading. Trust our factory's commitment to quality and precision in providing real-time data transmission solutions. Choose us as your preferred suppliers for reliable industrial data collection instruments

    Product Introduction

    A product called the SM100-M-8 HART data collector was created using an ARM microprocessor, a HART protocol modem chip, and a great deal of real-world experience. It offers great stability and dependability and is designed to meet the specifications of industrial items. To ensure real-time data transmission, the data collector is outfitted with a standard RS485 interface and gateway that can either convert data into MODBUS _ RTU or MODBUS _ TCP protocol to read data or transparently communicate data with intelligent instruments using HART protocol.

    The HART protocol instrument enables bidirectional data transmission without interfering with the 4 to 20 mA analog signal by superimposing a modulated digital signal on a 4 to 20 mA basis using the Bell202 Frequency Shift Keying (FSK) standard. An clever converter for bidirectional modulation and demodulation of digital and analog signals is the SM100-M series HART data collector.

    Product Features

    • Support simultaneous connection of 8 HART devices.

    • Support parallel and simultaneous scanning of all HART channels configured for the HART data collector.

    • Three-terminal electromagnetic full quarantine between HART channels and between HART and host power supply. Each channel adopts two-wire interface. The voltage of electromagnetic quarantine of HART module is not less than 1500 V. It supports the function of separating HART signal/4 ~ 20ma signal.

    • The quarantine voltage of RS485 interface and NET Ethernet interface shall not be lower than 1500 V.

    • Adopt the modular design of separating the HART module from the host, and support the function of replacing the HART module online in any channel.

    • Each channel is provided with an independent indicator light, which provides indication of HART equipment online and HART equipment communication status respectively.

    • Equipped with equipment status indicator light: operation/fault, communication interface, etc.

    • Data refresh rate per channel < 1 second.

    • Support Ethernet interface (speed not less than 100Mbps) and RS485 interface.

    • Support proprietary HART commands to read the HART ID of all HART devices.

    • Support configuration and operation mode, and support Telnet remote setting.

    • Support firmware program update.

    • Supports standard DIN rail mounting.

    • The equipment does not affect the transmission and accuracy of 4 ~ 20 mA analog signal in normal, power failure or fault, and the loop resistance is less than or equal to 250 ohms.

    • This equipment does not supply power to field instruments.

    • Compatible with HART protocol Ver5.0 and above.

    Main Parameters

    Power supply voltage DC 24V.
    Operating current < 80mA.
    Shell size 305 mm long × 160 mm wide × 35 mm high.
    Installation dimension 347.4 mm (L) × 35 mm (W) × 160 mm (H).
    Working temperature -20 ℃ ~ + 75 ℃.
    Humidity of working environment 5% ~ 95% (no condensation).

    Frequently Asked Questions

    How many HART devices can the SM100-M-8 connect to simultaneously?
    The SM100-M-8 HART data collector supports the simultaneous connection of up to 8 HART devices.
    What is the data refresh rate per channel for this collector?
    The data refresh rate per channel is less than 1 second, ensuring high efficiency and real-time data transmission.
    Does the SM100-M-8 affect the existing 4 to 20 mA analog signals?
    No, the equipment does not affect the transmission and accuracy of the 4 to 20 mA analog signal during normal operation, power failure, or fault conditions. The loop resistance remains less than or equal to 250 ohms.
    What protocols can the data collector convert data into?
    It can convert HART data into either MODBUS_RTU or MODBUS_TCP protocols to read data, or communicate transparently with intelligent instruments.
    What are the installation requirements and working temperature range?
    It supports standard DIN rail mounting and can operate stably in a temperature range of -20 ℃ to + 75 ℃.
    Does this collector supply power to field instruments?
    No, this equipment does not supply power to field instruments.