Fully Isolated HART to RS485 Converter SM101-W - China Suppliers & Factory for MODBUS-RTU Solutions
Product Specifications
Product Features
-
Equipped with standard RS485 communication interface and gateway, it can configure parameters, change communication baud rate and parity check bit. It is independent of the 1200 communication speed on the HART bus, thus improving the operation speed of the whole system.
-
Adopt industrial universal module shell, which is convenient for installation and commissioning.
-
It is equipped with special configuration software, which can configure the parameters of SM101-W series intelligent converter, and can communicate with HART protocol intelligent instrument through the intelligent converter.
-
Supports standard MODBUS_RTU and MODBUS_TCP protocols.
-
Support simultaneous connection of multiple HART protocol intelligent instruments.
-
Each HART channel is in quarantine with each other without affecting the instrument current output.
-
Support a variety of special HART protocol intelligent instruments, and can customize the instructions for reading special HART instruments.
-
The data update time is 0.8 seconds for one set. If four sets are connected, the data will be updated in 3.2 seconds.
-
Installation method: standard rail installation or fixed installation.
Main Parameters
Frequently Asked Questions
What communication protocols does the SM101 series intelligent converter support?
The SM101 series intelligent converter supports standard MODBUS_RTU and MODBUS_TCP protocols, enabling seamless integration into various industrial networks.
How does the converter handle multiple HART protocol instruments?
It supports simultaneous connection of multiple HART protocol intelligent instruments. Crucially, each HART channel is electrically isolated from the others, ensuring that the instrument current output remains unaffected.
What is the data update frequency for connected devices?
The data update time is 0.8 seconds for a single connected set. When multiple devices are configured, the update time scales linearly (for example, taking 3.2 seconds if four sets are connected).
What are the power supply specifications and operating environments?
The converter requires a DC 12 ~ 24 V input voltage (ripple ≤ 200 mA, current 100 mA). It operates reliably in temperatures ranging from -20 ℃ to +80 ℃ and relative humidity between 10% and 80%.
How is the SM101 converter physically installed?
Designed with an industrial universal module shell, the device supports standard DIN rail installation or fixed-mount installation, making commissioning simple and convenient.