0102
HART to 4-20mA Converter & Modbus Protocol: SM100-G Intelligent Alarm Controller from China Suppliers & Factory
Product Specifications
- Outfitted with a common RS485 communication interface for parity check, communication baud rate, and parameter tuning. It increases the system's overall operating speed because it is not dependent on the HART bus's 1200 communication speed.
- Adopt an industrial universal module shell, which makes commissioning and installation easier.
- It has specialized configuration software that allows it to set up the SM100-G intelligent alarm controller's parameters and connect to an intelligent instrument that uses the HART protocol. Support for the common RTU and MODBUS protocols.
- Capable of customizing the instructions for reading specific HART instruments, it supports a wide range of intelligent instruments with the HART protocol.
- The output interface takes the shape of a DO relay with two or four channels.
- With an output current of 1/2 4 ~ 20 mA.
- The power-off memory function eliminates the need to reset parameters after turning off the power.
- The alarm controller's operational state can be plainly seen via the status indicator.
- Method of installation: fixed installation or regular rail installation.
Product Features
SM100-G collects HART protocol and outputs 4-20mA and 485 simultaneously.
SM100-G can communicate with smart instruments using HART protocol and has an alarm function.
Main Parameters
Power Supply Input Voltage
DC 12 ~ 24 V
Current & Ripple Limit
100mA (Ripple ≤ 200 mA)
Enclosure Dimensions
145 mm L × 90 mm W × 73 mm H
Working Temperature
-20 ℃ ~ + 80 ℃
Relative Humidity
10% ~ 80%
Frequently Asked Questions
What communication protocols and interfaces does the SM100-G support?
The SM100-G supports the common RTU and MODBUS protocols. It features a common RS485 communication interface for parity check, baud rate configuration, and parameter tuning, which operates independently of the HART bus's 1200 communication speed to improve system speed.
Can the SM100-G output both 4-20mA and RS485 signals simultaneously?
Yes, the SM100-G is capable of collecting HART protocol data and outputting 4-20mA and 485 signals simultaneously.
What are the power supply requirements for this controller?
The device requires an input voltage of DC 12 ~ 24 V. The operating current is 100mA, and the power supply ripple must not exceed 200 mA.
Does the controller retain its settings if the power is turned off?
Yes, the SM100-G features a built-in power-off memory function that eliminates the need to reset parameters after turning off the power.
How is the SM100-G intelligent alarm controller installed?
The controller supports two methods of installation: fixed installation or regular rail installation, utilizing an industrial universal module shell for easier commissioning.
What are the environmental and physical limitations of the device?
The device has an enclosure dimension of 145 mm L × 90 mm W × 73 mm H. It operates in temperatures from -20 ℃ to +80 ℃ and relative humidity levels between 10% and 80%.