HART to Modbus & RS485 Intelligent Transmitter SM100-HHE - China Supplier & Factory for Reliable Solutions
Product Specifications
-
Equipped with two standard RS485 communication interfaces for parameter configuration, changing communication baud rate, and parity bit. It is independent of the 1200 communication speed on the HART bus, thereby improving the operating speed of the entire system.
-
Adopts an industrially universal module housing for easy installation and debugging.
-
Comes with dedicated configuration software for parameter setting of the SM100-HHE Series Intelligent Transmitter, and enables data communication with HART protocol-enabled intelligent instruments through the intelligent transmitter.
-
Support for standard MODBUS_RTU protocols.
-
Support Yokogawa HART protocol smart instrument.
-
Support a variety of special HART protocol intelligent instruments, and can customize the instructions for reading special HART instruments.
-
Each HART channel is isolated from each other without affecting the instrument current output.
Main Parameters
DC 12 ~ 24 V, the ripple of the power supply shall not be greater than 200 mV, and the current shall be 100mA.
116 mm long × 120 mm wide × 24 mm high.
-20 ℃ ~ + 80 ℃
10% ~ 80%
Product Features
-
SM100HHE supports 2 Modbus outputs.
-
SM100HHE supports connecting multiple HART instruments.
Frequently Asked Questions
How many Modbus outputs does the SM100HHE support?
The SM100HHE supports 2 Modbus outputs and supports standard MODBUS_RTU protocols.
What are the power supply requirements for the SM100-HHE series?
It requires an input voltage of DC 12 ~ 24 V. The power supply ripple must not exceed 200 mV, and the operating current is 100mA.
Can I connect multiple HART instruments to the transmitter?
Yes, the SM100HHE supports connecting multiple HART instruments. Additionally, each HART channel is isolated from the others to prevent interference with the instrument current output.
Does the device support Yokogawa or other special HART protocols?
Yes, it supports Yokogawa HART protocol smart instruments as well as a variety of special HART protocol intelligent instruments, with the capability to customize reading instructions.
What are the dimensions and environmental limits of the unit?
The shell size is 116 mm long × 120 mm wide × 24 mm high. It operates in temperatures from -20 ℃ to + 80 ℃ with a relative humidity range of 10% to 80%.
How does the RS485 interface design improve system speed?
It is equipped with two standard RS485 communication interfaces that operate independently of the 1200 communication speed on the HART bus, thereby enhancing the overall operating speed of the system.