SM100-G HART Intelligent Alarm Controller - China Suppliers and Factory for 4-20mA to MODBUS and RS485 Solutions
Product Specifications
- Outfitted with a common RS485 communication interface for parity check, communication baud rate, and parameter tuning. It increases the system's overall operating speed because it is not dependent on the HART bus's 1200 communication speed.
- Adopt an industrial universal module shell, which makes commissioning and installation easier.
- It has specialized configuration software that allows it to set up the SM100-G intelligent alarm controller's parameters and connect to an intelligent instrument that uses the HART protocol. Support for the common RTU and MODBUS protocols.
- Capable of customizing the instructions for reading specific HART instruments, it supports a wide range of intelligent instruments with the HART protocol.
- The output interface takes the shape of a DO relay with two or four channels.
- With an output current of 1/2 4 ~ 20 mA.
- The power-off memory function eliminates the need to reset parameters after turning off the power.
- The alarm controller's operational state can be plainly seen via the status indicator.
- Method of installation: fixed installation or regular rail installation.
Product Features
SM100-G collects HART protocol and outputs 4-20mA and 485 simultaneously.
SM100-G can communicate with smart instruments using HART protocol and has an integrated alarm function.
Main Parameters
Frequently Asked Questions
What communication interfaces does the SM100-G support?
The SM100-G is equipped with a common RS485 communication interface that supports standard RTU and MODBUS protocols, and it can communicate with smart instruments using the HART protocol.
Can the SM100-G output 4-20mA and RS485 signals at the same time?
Yes, the SM100-G is designed to collect HART protocol data and output 4-20mA (1/2 channels) and RS485 signals simultaneously.
What are the power requirements for this controller?
The controller requires a power supply input voltage of DC 12 ~ 24 V. The ripple of the power supply must not exceed 200 mA, and the working current is 100mA.
Do I need to reconfigure the parameters after a power failure?
No, the SM100-G has an integrated power-off memory function, which eliminates the need to reset parameters after turning off the power.
How is the SM100-G controller installed?
The device supports two installation methods: fixed installation or standard rail installation, housed inside an industrial universal module shell for easier commissioning.
What are the environmental limits for the SM100-G?
The SM100-G is built to operate under temperatures ranging from -20 ℃ to + 80 ℃ and relative humidity levels between 10% and 80%.