SM100-G HART Intelligent Alarm Controller - China Suppliers & Factory for 4-20mA and MODBUS Protocol
Product Specifications
- Outfitted with a common RS485 communication interface for parity check, communication baud rate, and parameter tuning. It increases the system's overall operating speed because it is not dependent on the HART bus's 1200 communication speed.
- Adopt an industrial universal module shell, which makes commissioning and installation easier.
- It has specialized configuration software that allows it to set up the SM100-G intelligent alarm controller's parameters and connect to an intelligent instrument that uses the HART protocol. Support for the common RTU and MODBUS protocols.
- Capable of customizing the instructions for reading specific HART instruments, it supports a wide range of intelligent instruments with the HART protocol.
- The output interface takes the shape of a DO relay with two or four channels.
- With an output current of 1/2 4 ~ 20 mA.
- The power-off memory function eliminates the need to reset parameters after turning off the power.
- The alarm controller's operational state can be plainly seen via the status indicator.
- Method of installation: fixed installation or regular rail installation.
Product Features
SM100-G collects HART protocol and outputs 4-20mA and 485 simultaneously.
SM100-G can communicate with smart instruments using HART protocol and has alarm function.
Main Parameters
DC 12 ~ 24 V, the ripple of the power supply shall not be greater than 200 mA, and the current shall be 100mA.
145 mm L × 90 mm W × 73 mm H.
-20 ℃ ~ + 80 ℃.
10% ~ 80%.
Frequently Asked Questions
What communication protocols and interfaces does the SM100-G support?
The SM100-G is equipped with an RS485 communication interface and supports common RTU and MODBUS protocols, alongside compatibility with the HART protocol for intelligent instruments.
Can the SM100-G output multiple signals simultaneously?
Yes, the SM100-G can collect HART protocol data and output both 4-20mA current signals and RS485 communication signals simultaneously.
What are the power requirements for the SM100-G intelligent alarm controller?
The controller requires a power supply input voltage of DC 12 ~ 24 V, with a current of 100mA and a power supply ripple not exceeding 200 mA.
Does the device retain parameters during a power outage?
Yes, the SM100-G features a built-in power-off memory function, which eliminates the need to reconfigure or reset parameters after the power is turned off.
What are the dimensions and installation methods for this controller?
The enclosure dimensions are 145 mm L × 90 mm W × 73 mm H. It can be installed using either a fixed installation method or a regular rail installation.
What are the environmental working limits of the SM100-G?
The device operates reliably in working temperatures ranging from -20 ℃ to +80 ℃, and within a relative humidity range of 10% to 80%.