0102
HART to MODBUS Transmitter SM100-HHE: Reliable China Suppliers & Factory for Intelligent 4-20mA Solutions
Product Specifications
-
Equipped with two standard RS485 communication interfaces for parameter configuration, changing communication baud rate, and parity bit. It is independent of the 1200 communication speed on the HART bus, thereby improving the operating speed of the entire system.
-
Adopts an industrially universal module housing for easy installation and debugging.
-
Comes with dedicated configuration software for parameter setting of the SM100-HHE Series Intelligent Transmitter, and enables data communication with HART protocol-enabled intelligent instruments through the intelligent transmitter.
-
Support for standard MODBUS _ RTU protocols.
-
Support Yokogawa HART protocol smart instrument.
-
Support a variety of special HART protocol intelligent instruments, and can customize the instructions for reading special HART instruments.
-
Each HART channel is isolated from each other without affecting the instrument current output.
Main Parameters
Power Supply Input
DC 12 ~ 24 V, ripple ≤ 200 mV, current 100mA
Shell Dimensions
116 mm (L) × 120 mm (W) × 24 mm (H)
Working Temperature
-20 ℃ ~ + 80 ℃
Relative Humidity
10% ~ 80%
Product Features
-
SM100HHE supports 2 Modbus outputs
-
SM100HHE supports connecting multiple HART instruments
Frequently Asked Questions
It is equipped with two standard RS485 communication interfaces, which are used for parameter configuration, changing the communication baud rate, and setting the parity bit. It is independent of the 1200 communication speed on the HART bus.
Yes, the device fully supports standard MODBUS _ RTU protocols, making it highly compatible with various industrial control systems.
The required input voltage is DC 12 ~ 24 V. The ripple of the power supply must not exceed 200 mV, and the operating current is 100mA.
Yes, the SM100HHE supports connecting multiple HART instruments. Crucially, each HART channel is isolated from the others, ensuring that the instrument current output remains unaffected.
The shell dimensions are 116 mm in length × 120 mm in width × 24 mm in height. It is designed to work reliably in temperatures ranging from -20 ℃ to + 80 ℃ and relative humidity between 10% and 80%.
Yes, it supports Yokogawa HART protocol smart instruments as well as a variety of special HART protocol intelligent instruments. Users can also customize instructions for reading special HART instruments.